1. RUSTGRIP ® PATENT | ||
2. Full List of Testing and Certifications (151 pages) | ||
3. ASTM ( American Society for Testing and Materials ) | ||
B 117 Standard Practice for Operating Salt Spray (Fog) Apparatus The coated panels were exposed in a Salt Fog Chamber maintained in accordance with B 117, for 15,000 hours. The panels were evaluated periodically for blistering overall in accordance with D 714 and rust staining overall in accordance with D 610 and achieved a perfect 10 in both at the end of the 15,000 hours | Passed 15,000 hours |
|
C 411 96 Hour Hot Surface Performance | Passed | |
- Tested at 147°C (293°F) | ||
- No Ignition, Smoking, or Smoldering | ||
- No Change in Colour | ||
D 522 - Flexibility | Passed | |
D 1308 - Distilled Water Resistance (Immersion 24 hours) | Passed | |
- .010" Tin plated Steel | ||
- 1/4" Steel or Aluminum | ||
- 24 Hour Chemical Resistance (12 Reagents) - Spot Test on Glass | ||
D 1475 - Volatile Organic Content | Passed | |
D 1653 - Water Vapor Transmission | Passed | |
D 2369 - Volatile Organic Content | Passed | |
D 2370 - Visco-Elastic Properties | Passed | |
D 2486 - Scrub Resistance | Passed | |
- Black Plastic - No Break thru after 12 cycles | ||
D 2794 - Direct Impact Resistance | Passed | |
D 3273 / D 3274 - Mildew Resistance | Passed | |
D 3359 Adhesion and Penetration testing | Passed | |
- Penetration through 18 layers of Oil Base Paint | ||
- Rated 5A = Excellent | ||
- MICRO PHOTOGRAPH | ||
D 3960 / D 4017 - Volatile Organic Content | Passed | |
D 4060 Tabor Abrasion Resistance | Passed | |
- Dry Abrasion Resistance | ||
- 1000 Cycles with a CS 17 Wheel, 1000 gram Load | ||
- 18 milligram loss per 1000 Cycles, rated Excellent | ||
D 4541 Standard Method for Pull-Off Strength of Coatings using Portable Adhesion Testers | Passed | |
- Average Pull-Off Strength = 1,467 psi | ||
D 5894-10 Standard Practice for Cyclic Salt Fog/UV Exposure of Painted Metal, (Alternating Exposures in a Fog/Dry Cabinet and a UV/Condensation Cabinet.) Blistering & Rusting Evaluation. | Passed 1000, 5000, 10,000 Hours | |
D 6904 Standard Practice for Resistance to Wind-Driven Rain for Exterior Coatings Applied to Masonry | Passed | |
D 7088 Standard Practice for Resistance to Hydrostatic Pressure for Coatings Used in Below Grade Applications Applied to Masonry | Passed | |
E 108 Standard Test Method for Spread of Flame of Roof Coverings | Class "A" Rating | |
E 1795 BioHazard Encapsulation Certification | Conforms to all requirements | |
- Direct Impact Resistance | ||
- Adhesion | ||
- Dry Abrasion Resistance | ||
- Water Vapor Transmission | ||
- Flexibility | ||
- Water and Chemical Resistance | ||
- Water Immersion | ||
- Surface Burning Characteristics | ||
- Volatile Organic Content | ||
- Weathering (1000 hours) | ||
- Aging (interior and exterior) | ||
- Scrub Resistance | ||
- Mildew Resistance | ||
- Paint / Repair Ability | ||
- Tensile Properties | ||
E 84 - Surface Burning Characteristics | Passed | |
G 20Standard Test Method for Chemical Resistance of Pipeline Coatings. | ||
G 85 Prohesion over rusted metal | Passed | |
- Rated 9 (out of a possible 10 rating) | ||
4.US Army Corp of Engineers | ||
Passed | ||
Moisture-Cure Urethane Coatings for Compliance with Industry Specifications SSPC Paint 41 | ||
5.Society of Petroleum Engineers | ||
Passed | ||
Society of Petroleum Engineers and Workstrings International selected RUST GRIP as the final choice for protection of steel from Salt Water and ZnBr Completion Fluids. | ||
6. Factory Mutual Approval | ||
- ASTM E 108 Tested and Approved for Roofing and all other Applications |
Class A | |
*Superior Products International II, Inc. is an active member of the NRCA. | ||
( National Roofing Contractors Association ) | ||
7. WINDOW CYCLING Test | ||
Opening/Closing of treated window to measure friction/wear | Passed | |
- Completed 20,000 cycles of opening / closing the window. 54 years of protection | ||
8. DNV Certification | Passed | |
- DNV Audit and DNV Compliant | Passed | |
- ASTM B 117, D 163, D 522, D 3359, D 4060, & E 1795 | ||
- Official DNV Certification of RUSTGRIP ® for Maritime usage. | DNV Certified | |
9. State of Louisiana Department of Transportation | ||
10. State of Oklahoma Department of Transportation | ||
11. State of Tennessee Department of Transportation | ||
12. ABS Coast Guard Approval | ||
13. Transport Services Division Pavements & Structures Section – Materials Group | ||
Pull tests rated equal to 1100 psi. | ||
14. Aramco Oil in Saudi Arabia Approval for Asbestos Encapsulation | Approved Product | |
15.VTEC Laboratories INC | ||
Thermal analysis | ||
16. LEED - Leadership in Energy & Environmental Design | Approved product | |
May 1, 2007 (revised May 21, 2007) (Washington, DC) – The U.S. Green Building Council (USGBC) has announced that projects seeking certification under the LEED ® Green Building Rating System™ can now earn an "Innovation in Design" point by using the Cradle to Cradle program for certified building products. | ||
GOLD CERTIFICATION | ||
17. USDA (United States Department of Agriculture ) | ||
- Letter of Authorization from USDA Product Safety Branch | USDA Approved | |
- Letter of Written Certification as Accepted by USDA from Manufacturer | Approved | |
- Environmentally safe and safe for use around animals | Passed | |
18. CFIA Canadian Food Inspection Agency | ||
Accepted construction material | Passed | |
19. China Center for Technical Testing | ||
National Measurement M0729 | ||
GB/T 1771-91 - Resistance to Salt Fog (2000 hours) | Passed | |
GB/T 1866-88 - Manual Aging (2000 hours) | Passed | |
GB/T 10834-88 - Resistance to Salt Water (1000 hours) | Passed | |
GB/T 5219-85 - Adhesion (pulling apart method) | 4.07MPa | |
GB/T 1733-93 - Boiling Water Immersion | 8 Hours |